NICHOLAS HACKO - FINE WATCHES
Master Watchmaker, Clockmaker and Jeweller (since 1981)
rolex omega panerai iwc patek and other fine watches by Nicholas Hacko Sydney
nick@clockmaker.com.au
Suite 403, Level 4, Culwulla Chambers, 67 Castlereagh St. Sydney 2000 NSW Australia
Phone: 02 9232 0500     Fax: 02 9233 2273

The Mysterious Rolex Submariner 5512

Here is the story of "mysterious" Rolex 5512 from 1960s that came in with owners note: "I had left my 5512 Submariner with a local watchmaker to service a few weeks ago. Anyway yesterday he tells me he cannot adjust the accuracy of the watch below 30 minutes a day. He doesn't know what is exactly wrong...

That sounds like an interesting challenge and I really couldn't wait to get into it!

Bracelets were removed and serial numbers checked and recorded

This is the most exciting moment: what mystery is hidden inside?

Cal. 1570 movement is held with 2 clamps

Initial timing machine reviled that 'hearth beat' reading was very erratic but somehow consistent. But the error was only 40 seconds per day, not 30 minutes as reported.

Further inspection of balance wheel reviled poorly aligned hairspring

and lose weight screw (C). The hairspring was rubbing against spoke of balance wheel. This could be possible reason for excessive gain.

hairspring was realigned to correct position (from A to B) which resulted in much better timekeeping.

The amplitude was much better, the bal. wheel was resonating at 19,800 bph which is correct for cal. 1570.

Yet the watch was still gaining like crazy!
Obviously there was another problem hidden deeper inside! Movement was disassembled once again.

This time I was looking for train wheel with incorrect tooth count. New set of original Rolex cal 1570 wheels was there as reference (green)

... and culprit is 4th wheel ! Although of exactly same diameter as correct wheel, this one has different number of tooth!

the watch was reassembled again and voila - the excessive gain magically disappeared!
But could this well-beaten up 5512 keep even better time, perhaps within chronometer specification? Let's see...
Once again, the complete movement was disassembled, cleaned, lubricated and adjusted. Fast forward - 2 hours later the result speaks for itself.

Final adjustment: +1 sec / day. Naturally, once worn on the wrist the actual error could be slightly higher, I would still expect this 5512 to perform within chronometer specification.

And finally one mystery will probably remain unsolved for ever: who, why and when fitted the wrong 4th wheel in the first place?

Feel free to email your comments.

Return to Journal index | Watches for sale

vintage rolex and other fine watches for sale by Nicholas Hacko Watchmaker - Sydney FACT: 35% of all watches offered for sale actually never reach my website - because they are sold to my existing customers and mail list subscribers. NEVER MISS A GREAT DEAL AGAIN !
From now on, you should be the first one to know. Subscribe to watchmakers opt-in announcement list NOW.

Instant 'in box' notification as new stock becomes available Discount on selected watch winders Watches under $A 1000 Trade-in and unrestored stock BELOW DEALERS COST specials Regular monthly specials Private sellers stock

watch winders for rolex and other fine watches

WE SELL AUTOMATIC WATCH WINDERS suitable for ROLEX, PANERAI, OMEGA and all other automatic watches

CLICK HERE FOR OUR COMPLETE RANGE OF WINDERS
PRICED FROM $A 289 TO $A 998


Ladies Rolex watches for sale Watch windersCustomer testimonials Date your Rolex : serial numbers and production data Rolex case sizes